šµļø The idea for this weekās Newsletter came from the request I received from a client, who wants to design a CLLC OBC Charger Transformer. Without getting into details, letās just say that this specific project got me thinking and going back to my Magnetics Notes once more.
But then I realized that I didnāt have a clear document that I could print and look up to when I need to build a Transformer model in LTspice or Suzuka, from measurements or the other way around. You know, Iām used to calling this type of notes āGOLDā. After thinking it twice, I decided to make this Newsletter a reference text for all of you!
š The Transformer model that we all know
In Figure 1, if we omit the capacitors Cp, Cs we have a power source, a Transformer model, and a load resistor. Adding the series capacitor, we have the trending CLLC topology that is currently trending in the automotive world.
Figure 1. Transformer model for a SS WPT system identical to CLLC converter
š Can you believe I took this picture 7 years ago, when I was writing my thesis for the development of a complete wireless power system (WPT)? The industry back then hadnāt made the decision to move electric just yet (āthanks, Elonā). Back then, wireless power transfer was a trending topic with multiple new papers published across the globe. Mainly, the goal of the research groups was to explain the various modes of operation of WPT systems.
Figure 1 depicts the SS WPT topology because the capacitors are connected in series with Transformer. The only major difference between an SS WPT system and a CLLC Converter is the coupling factor k, not considering operation modes. You see in a WPT system, the inductors are facing each other and behave like a loosely coupled transformer.
š Useful definitions and the connection to measurements
First of all:
LP is the primary inductance.
LM is the magnetizing inductance.
Llkp is the primary leakage inductance.
When we build an inductor and choose x turns, given the AL value of the material, we get the inductance L=x2AL. If that is the primary winding of a Transformer, we call this inductance, primary inductance LP . Now, if the Transformer was an ideal one, then the coupling factor is equal to 1, and there are zero leakage inductances.
āļø In the case of a real Transformer, as modelled in Figure 1, the primary āisnāt coupledā to the secondary completely, so LP is split between the leakage and the magnetizing inductance, depending on the coupling factor. The magnetizing inductance is the largest percentage of the primary inductance, responsible for power transfer, whilst the rest acts like an inductor storing energy in series.
As said:
Usually, the coupling factor k has values like 0.999, so almost all primary inductance is magnetizing inductance with a tiny percentage of it is left as leakage inductance Llkp. But in a WPT application, or in a resonant topology like LLC or CLLC, the coupling factor can take much lower values. Also:
ā Turns ratio n is known.
ā LP is known from the AL value and turns and can be easily measured if we just measure the primary inductance with all other windings open.
ā The coupling k factor is not known. If we know k, then we can calculate the primary and secondary leakage inductances and the Transformer model of Figure 1 is complete!
š¤ Do you know how to measure the k factor?
If your answer is āwhat do I need the k factor for, I just short the secondary and measure the leakage in the primary, which I call primary leakageā, then youāre right only if you assume the k factor is very close to unity.
ā ļø When however, you design resonant Transformers you are about to commit mistakes thinking that way! Letās look at what exactly happens if we short the secondary winding and measure from the primary side:
Figure 2. Shorting the secondary and measuring inductance at the primary side
As seen in Figure 2, we donāt measure the primary leakage, but more correctly the ālumpedā/ āeffectiveā/ ātotalā leakage of the transformer that way. Well, that leakage is close to the primary leakage if we assume that the secondary leakage inductance is much lower than the magnetizing inductance, thus the parallel combo value is close to zero. You see the fault in these assumptionsā¦
š” Instead of assumptions, we can write the following for the equation:
So, the total inductance which I like to call Lshort is:
And after a page long of equation manipulations:
⨠Bingo! Now you can easily calculate k with this easy measurement and define all leakage inductances exactly.
An example:
Figure 3. Example LLC Transformer
Calculating the k factor (in an LLC- center tap the short test is done with one of the 2 secondaries):
So:
ā” One key skill is connecting theory and practice, with knowledge about parasitic elements and assumptions made in the process, no matter of the subject.. Iāve said it before, and Iāll say it again!
š Hopefully you like this bright example. See you in the next one.
-------------------------------------------